Where to fit pressure gauges — the cheapest diagnostics you can buy

Aqua Filtration System, Faridabad · 9+ years in water treatment · Updated September 2026

Short answer: Fit gauges before and after every filter and across the membrane housing. The difference between two gauges tells you what is choking, what is worn and what is working — for about ₹315 each.

A plant with gauges can be diagnosed in fifteen minutes. Without them, the same fault takes hours of guesswork and often ends with a part being replaced unnecessarily.

Glycerine filled pressure gauge
Glycerine filled pressure gauge

Where they belong

PositionWhat it tells you
Feed pump outletPump is delivering, or is worn
Before and after cartridge filterWhen to change the cartridge — the most useful pair
Before and after media filterWhen to backwash
Before and after softenerBed compaction or channelling
HP pump outlet (membrane feed)Operating pressure
Membrane reject linePressure drop across the elements
If you only fit one pair, put it across the cartridge filter. That single measurement prevents more problems than any other instrument on a small plant.

Reading pressure drop

Pressure drop (ΔP) is inlet minus outlet:

ΔP across cartridgeMeaning
0.2 – 0.3 kg/cm²New filter, normal
0.5 kg/cm²Roughly half life
0.8 kg/cm²Prepare to change
Above 1.0 kg/cm²Change now

The simple rule: change when ΔP reaches double the new-filter reading.

Reading the membrane

Across the membrane housing, ΔP tells you about fouling:

See our membrane monitoring guide.

Choosing the range

The gauge should read your normal pressure at roughly the middle of its scale. Too large a range and you cannot see small changes; too small and the gauge will be damaged.

ApplicationNormal pressureGauge range
Feed line, pre-treatment2 – 4 kg/cm²0 – 7 kg/cm²
Cartridge filter2 – 4 kg/cm²0 – 7 kg/cm²
RO membrane feed10 – 15 kg/cm²0 – 25 kg/cm²
Softener or media filter2 – 4 kg/cm²0 – 7 kg/cm²

Glycerine filled gauges

Where a pump causes vibration or pressure pulsation, the needle flickers constantly and the mechanism wears. A glycerine filled gauge damps this:

Use glycerine filled at the pump outlet and on dosing lines. A dry gauge is fine on quiet parts of the line.

Fitting them

  1. Fit an isolation cock under each gauge, so it can be replaced without draining the line
  2. Mount at eye level where possible — a gauge nobody can read gets ignored
  3. Use PTFE tape, four to six turns, and do not over-tighten
  4. On a dosing line, fit a diaphragm seal if the chemical would attack the gauge

Record the readings

Gauges only help if somebody looks at them. Keep a simple weekly record:

DateCart inCart outΔPMembrane feedNote
01/093.53.20.312New cartridge
15/093.53.00.512Normal
01/103.52.60.912.5Change cartridge soon

This record shows you the trend, so cartridge changes and cleanings can be planned rather than forced.

What gauges tell you that nothing else does

Consider a plant with reduced output. Without gauges you might replace the membrane, the pump, or both. With gauges:

Full diagnosis is in our RO troubleshooting guide.

What to order

See our pressure gauges range. Tell us:

  1. Where it will be fitted
  2. Normal operating pressure
  3. Connection size and bottom or back entry
  4. Whether the line has vibration (for glycerine filled)

Order pressure gauges

Tell us where they will be fitted and your operating pressure, and we will supply the right range and type.

📞 9910646957

Frequently asked questions

Where should pressure gauges be fitted on an RO plant?

Before and after every filter, and across the membrane housing. If you only fit one pair, put it across the cartridge filter, since that single measurement prevents more problems than any other instrument.

What pressure drop means the cartridge needs changing?

About zero point two to zero point three kg per cm2 on a new filter, rising to above one kg when it needs changing. The simple rule is to change when the drop reaches double the new-filter reading.

What gauge range should I choose?

One where your normal pressure sits around the middle of the scale. Too large a range and you cannot see small changes, too small and the gauge will be damaged. Pre-treatment usually uses zero to seven kg, membrane feed zero to twenty five.

When is a glycerine filled gauge worth using?

Where a pump causes vibration or pressure pulsation. The glycerine damps the needle so it is readable and the mechanism lasts much longer. Use them at pump outlets and on dosing lines.

Why fit an isolation cock under each gauge?

So the gauge can be replaced or checked without draining the line. It is a small addition that makes maintenance considerably easier.