Using a DO meter in an ETP — and cutting the power bill

Aqua Filtration System, Faridabad · 9+ years in water treatment · Updated September 2026

Short answer: DO stands for Dissolved Oxygen. In the aeration tank of an ETP or STP it should be 1.5 to 3 mg/L. Below that the bacteria weaken and treatment fails; above it you are simply wasting electricity.

That is the real benefit here — in an ETP the blower consumes 60 to 70 percent of the electricity, and DO monitoring can produce substantial savings.

Dissolved oxygen meter
Dissolved oxygen meter

What happens in an aeration tank

Bacteria consume the organic load, but they need oxygen to survive. The blower supplies air, oxygen dissolves into the water, and the bacteria keep working.

The electricity saving — actual numbers

Suppose your blower is 5 HP running 24 hours:

If DO is running at 5 mg/L and you bring it down to 2.5, blower running time falls considerably. Even a 20 percent saving is around ₹4,000 a month.

What this means: on a large plant a DO meter at ₹68,250 pays for itself in electricity savings within roughly 15 to 18 months. On a small plant it takes considerably longer.

Target DO levels

LocationDO (mg/L)
Aeration tank (general)1.5 – 3.0
MBBR aeration2.0 – 4.0
SBR — aeration phase2.0 – 3.0
SBR — anoxic phaseBelow 0.5 (deliberately)
Discharge to a watercourseAbove 4.0 (commonly)

DO meters available

ModelFeaturePrice
D.O. Meter with sensorBasic online meter₹68,250
D.O. Meter with RS485Data to panel or SCADA₹72,450
D.O. sensor (separate)Sensor replacement only₹61,950
Note: the sensor alone costs almost as much as the complete meter (₹61,950 against ₹68,250). The sensor is by far the most valuable part, so its maintenance really matters.

Where to place the sensor

  1. In the middle of the aeration tank — not in a corner, where mixing is good
  2. Not directly above a diffuser — bubbles striking the sensor give a falsely high reading
  3. Depth: around half the tank depth
  4. Easy to withdraw — for cleaning and calibration

Sensor care — this really matters

Cheaper alternatives

If ₹68,000 is not in the budget right now:

What to monitor alongside DO

DO alone does not give the whole picture. In an ETP you also want:

A common situation

On many plants DO reads perfectly well yet treatment still fails. The usual reasons are:

So DO should always be read alongside pH and MLSS.

Set up ETP monitoring

Send your plant KLD, blower HP and current electricity bill, and we will estimate how quickly a DO meter would pay for itself.

📞 9910646957

Frequently asked questions

What DO level should an aeration tank have?

Generally one and a half to three mg per litre. Below that the bacteria weaken and treatment fails, and above it there is no additional benefit, only wasted blower electricity.

How does a DO meter save electricity?

In an ETP the blower accounts for sixty to seventy percent of electricity consumption. If DO is running higher than necessary, reducing blower operation produces substantial savings. On a large plant the meter can pay for itself within about fifteen to eighteen months.

How often should a DO sensor be cleaned?

Weekly. Biofilm builds up on the sensor and makes it read low, which leads you to run the blower harder and waste more electricity. Regular cleaning is therefore essential.

DO is correct but treatment is still failing — why?

Common reasons are a dirty sensor giving a false reading, poor mixing so that DO is adequate in only part of the tank, or low MLSS meaning too few bacteria. Incorrect pH also stops bacteria working despite adequate oxygen.

Is there a cheaper alternative to an online DO meter?

You can check with a portable DO meter two or three times a week and set the blower timer accordingly. Simply putting the blower on a timer also produces worthwhile savings, and an energy meter panel shows consumption continuously.