When an electromagnetic flow meter is worth it — and when it is not

Aqua Filtration System, Faridabad · 9+ years in water treatment · Updated September 2026

Short answer: Choose an electromagnetic flow meter only if one of three things is true — the line is larger than 40NB, the water is dirty or chemically aggressive, or you need the reading in a panel or SCADA system. Outside those cases, spending ₹30,000 and upwards makes no sense; a rotameter or digital meter will do the job.

This is the most expensive flow meter we supply, so it is worth understanding before buying. In ETP and STP plants people often skip it and then have to fit one anyway to meet pollution board requirements.

Aster MAG-FLOW 650 electromagnetic flow meter
Aster MAG-FLOW 650 electromagnetic flow meter

How it works — with no moving parts

Coils around the pipe create a magnetic field. As water passes through that field it generates a small voltage, and that voltage is directly proportional to the flow. The meter measures the voltage and converts it into a flow reading.

This means nothing rotates inside the pipe — no float, no impeller. As a result:

One important condition: an electromagnetic meter only works on conductive liquids, meaning water with some dissolved solids in it. Normal water, raw water and effluent are all fine. But RO permeate and DM water will not work, because that water does not conduct electricity. Use a rotameter or FT-650 on those lines.

Four situations where it is necessary

1. Lines larger than 40NB

On a large line a rotameter becomes physically big, expensive and adds pressure drop. Above 50NB an electromagnetic meter is the practical choice.

2. Dirty water — ETP, STP, raw water

A rotameter tube clouds over within a few months here and the reading disappears, and deposits also build up on the float. An electromagnetic meter simply does not have this problem.

3. Pollution board requirements

ETP and STP discharge flow has to be recorded. That needs a meter with an output that can transmit data — usually together with a telemetry modem.

4. Chemical or acid lines

These need PTFE lining. Standard lining degrades in acid. The PTFE version costs roughly 10 to 30 percent more, but on an acid line the meter will not survive without it.

Size chart and prices

Note that ranges in this category are given in m³/hr. 1 m³/hr equals 1,000 LPH.

SizeRange (m³/hr)Equivalent (LPH)StandardPTFE
25NB0.2 – 10200 – 10,000₹30,450₹34,125
40NB1 – 201,000 – 20,000₹34,125₹40,425
50NB2 – 352,000 – 35,000₹38,325₹51,450
65NB4 – 604,000 – 60,000₹44,625₹56,700
80NB6 – 906,000 – 90,000₹44,625₹58,800
100NB7 – 1407,000 – 1,40,000₹53,550₹71,400
150NB10 – 30010,000 – 3,00,000₹69,300₹90,300

When it is a waste of money

Four installation essentials

  1. The pipe must always be full. A partly full pipe gives a wrong reading. Fit the meter in a low section of pipe or on a rising line, never on a falling line.
  2. Proper earthing is essential. Without it the reading wanders. This is the single most common installation error.
  3. Allow air to escape. Trapped air causes errors, so an air release valve (25NB) should be fitted.
  4. Leave straight pipe — 5 diameters upstream and 3 downstream.

Sending the data further

To get the reading to a control room or a pollution board server, the meter is paired with a telemetry modem (₹13,650) or a 4G modem with RS485 input (₹9,450). For logging on a laptop, an RS485 to USB converter (₹6,300) is enough.

Get the right magnetic meter for your plant

Send us your flow in m³/hr or LPH, the pipe size and the type of liquid — we will confirm the correct model and lining.

📞 9910646957

Frequently asked questions

Why does an electromagnetic flow meter not work on RO permeate?

The meter relies on the conductivity of the water. RO permeate and DM water have very low dissolved solids, so they do not conduct well and the meter receives no usable signal. On those lines a rotameter or an FT-650 digital meter should be used instead.

When is PTFE lining necessary?

When the line carries acid, alkali or any aggressive chemical, such as an ETP dosing line or a pickling plant. Standard rubber lining degrades within a few months in those conditions. The PTFE version costs more but there is no alternative there.

The meter reading keeps fluctuating — what should I check?

Check the earthing first, as that accounts for the majority of such cases. Then confirm the pipe is completely full and that no air is trapped in the line. Fitting an air release valve usually resolves it.

How long does an electromagnetic flow meter last?

It has no moving parts, so with correct installation and the right lining it will run for many years. Unlike a rotameter float, there is nothing inside that needs periodic replacement.

Which size should I choose for an ETP or STP?

Work out your discharge flow in m3/hr and choose a size where that flow sits mid-range. For example 20 KLD is roughly 0.85 m3/hr, for which 25NB is adequate. The line size also has to match, so please send us both your flow and pipe size.