RO recovery and reject water — how much is normal

Aqua Filtration System, Faridabad · 9+ years in water treatment · Updated September 2026

Short answer: Recovery is the proportion of feed water that becomes permeate. On typical Indian borewell water it should be 60 to 70 percent. Pushing it higher to save water scales the membranes, and a set of membranes costs far more than the water saved.

Recovery % = (Permeate flow ÷ Feed flow) × 100
ZeroScale 2000 LPH RO plant
ZeroScale 2000 LPH RO plant

Why recovery is limited

As permeate is removed, the remaining water becomes more concentrated. At 75 percent recovery, the reject stream is four times as concentrated as the feed.

At some point the salts in that concentrated stream exceed their solubility and crystallise — on the membrane surface, usually on the last element in the series.

So recovery is not a free choice. It is limited by your feed water chemistry, and exceeding that limit damages membranes regardless of how much antiscalant you dose.

Safe recovery by feed TDS

Feed TDSRecoveryReject concentration factor
Below 50070 – 75%3.3 – 4×
500 – 1,00065 – 70%2.9 – 3.3×
1,000 – 2,00060 – 65%2.5 – 2.9×
2,000 – 4,00050 – 60%2.0 – 2.5×
Above 4,00040 – 50%1.7 – 2.0×

Hardness matters as much as TDS. Very hard water needs lower recovery even at moderate TDS, unless it is softened first.

Measuring your actual recovery

  1. Measure permeate flow with a rotameter
  2. Measure reject flow with another rotameter
  3. Feed = permeate + reject
  4. Recovery = permeate ÷ feed × 100

Example: permeate 750 LPH, reject 400 LPH → feed 1,150 → recovery = 65 percent.

Rotameter placement is covered in our flow meter guide.

Adjusting recovery

Recovery is set by the reject valve. Closing it increases recovery, opening it reduces recovery.

Do not adjust the reject valve to chase output. If permeate flow has fallen, closing the reject valve will appear to restore it — but you have simply raised recovery, which accelerates the scaling that caused the problem in the first place. Diagnose the real cause instead.

What happens at excessive recovery

  1. Reject stream becomes more concentrated
  2. Salts exceed solubility on the last element
  3. Scale forms, flow falls, pressure rises
  4. Operator closes the reject valve further to compensate
  5. Scaling accelerates
  6. CIP cleaning recovers less each time
  7. Membranes replaced early

This cycle is common and entirely avoidable.

Minimum reject flow

There is also a minimum reject flow per element, required to sweep the membrane surface and carry concentrated water away. Falling below it causes scaling even if the overall recovery figure looks acceptable.

This is why on multi-element systems the reject flow at the last element matters most — it sees the most concentrated water with the least flow.

Using the reject water

Reject water is not sewage — it is simply concentrated feed water. Depending on its TDS it can be used for:

Reject TDSPossible uses
Below 2,000Gardening (salt tolerant plants), floor washing, toilet flushing
2,000 – 4,000Floor washing, vehicle first rinse, cooling tower make-up (with treatment)
Above 4,000Limited use, mainly disposal
Recovering the reject for secondary use is far better than raising recovery. You save the same water without any risk to the membranes.

How to raise recovery safely

If you genuinely need higher recovery, the correct approach is to change the water chemistry, not just close the valve:

Each of these raises the safe recovery limit rather than simply exceeding it.

Monitoring

A rising recovery figure that nobody set deliberately usually means permeate flow is falling — the first sign of fouling. See our membrane monitoring guide.

Optimise your recovery

Send your feed TDS, hardness and current flows, and we will advise on the safe recovery and how to improve it.

📞 9910646957

Frequently asked questions

What is RO recovery?

The proportion of feed water that becomes permeate, calculated as permeate flow divided by feed flow. On typical Indian borewell water it should be sixty to seventy percent.

Why can I not simply increase recovery to save water?

Because the reject stream becomes more concentrated as recovery rises, and at some point salts exceed their solubility and crystallise on the membrane. A set of membranes costs far more than the water saved.

What recovery is safe for my water?

It depends on feed TDS and hardness. Seventy to seventy five percent below five hundred TDS, sixty to sixty five percent between one and two thousand, and forty to fifty percent above four thousand.

Should I close the reject valve if permeate flow falls?

No. That simply raises recovery and accelerates the scaling that probably caused the flow drop. Diagnose the real cause instead, which is usually fouling or scaling.

Can the reject water be used?

Yes. Below two thousand TDS it can be used for gardening with salt tolerant plants, floor washing or toilet flushing. Recovering reject for secondary use is far better than raising recovery, because it saves the same water without risking the membranes.