WTPeSTORE™ — powered by Aqua Filtration System 📞 9910646957
🌐 Read in your language:

What water tests you actually need before buying a plant

Aqua Filtration System, Faridabad · 9+ years in water treatment · Updated September 2026

Short answer: Before specifying any treatment, you need at minimum TDS, hardness, pH, iron, turbidity and chlorine. Without these figures, any plant specification is guesswork — and a plant designed for the wrong water either fails or costs far more to run than it should.

Several of these you can test yourself with inexpensive kits.

SDI test kit
SDI test kit

The essential six

ParameterWhy it mattersTest
TDSDecides RO or notTDS meter, ₹2,730
HardnessDecides softener size and antiscalantHardness kit, ₹1,050
pHAffects treatment chemistrypH indicator, ₹7,035
IronFouls resin and membranesLaboratory
Turbidity / SDIDecides pre-filtrationSDI kit, ₹5,565
ChlorineDamages RO membranesDPD test kit

What each result means

TDS

TDS (ppm)Implication
Below 200RO may not be needed
200 – 500Acceptable for most uses
500 – 2,000RO recommended
Above 2,000RO needed, recovery limited

Hardness

Hardness (ppm)Implication
Below 150Softening usually not needed
150 – 300Softening recommended
Above 300Softening needed, especially for boiler

See our hard water effects guide.

Iron

Above 0.3 ppm, iron must be removed first. It fouls softener resin and RO membranes, and the fouling is difficult to reverse. Iron removal goes before the softener, not after.

SDI

SDI is more relevant to RO than turbidity, because it detects very fine particles a turbidity meter misses. See our turbidity and SDI guide.

Additional tests for specific situations

SituationAlso test
Boiler feedAlkalinity, silica, conductivity
Drinking waterBacteria, nitrate, fluoride, arsenic
High recovery ROSulphate, silica, barium
Surface water sourceOrganic matter, colour, bacteria
Coastal areaChloride, sodium
Industrial areaHeavy metals

What you can test yourself

These are the ones you need regularly, so owning the kits pays for itself quickly.

What needs a laboratory

For a new plant, get one full laboratory analysis done. It costs a few thousand rupees but it is the foundation of the entire design. Specifying a plant without it means guessing, and a wrongly specified plant costs far more.

Sampling correctly

A bad sample gives a bad result regardless of how good the laboratory is:

  1. Let the water run for a few minutes before sampling — do not take stagnant pipe water
  2. Use a clean container, rinsed with the same water
  3. Fill completely, leaving no air gap where testing dissolved gases
  4. Label with date, time and sampling point
  5. Deliver to the laboratory quickly — some parameters change within hours
  6. For bacteria, use a sterile container from the laboratory

Test at different times

Water quality changes. Borewell TDS often rises through summer as the water table drops, and surface water turbidity rises sharply in monsoon.

So design for the worst case, not the day you happened to sample. If possible, test in both summer and monsoon before finalising a design.

Routine testing once running

TestFrequency
Feed and permeate TDSDaily
Hardness after softenerDaily
Chlorine before membraneDaily
pHDaily
SDIMonthly
Full analysisAnnually, or when the source changes

See our test kits range.

Get your water tested

Send us your water analysis and what you need the water for, and we will recommend the right treatment.

📞 9910646957

Frequently asked questions

Which water tests are needed before buying a treatment plant?

At minimum TDS, hardness, pH, iron, turbidity or SDI, and chlorine. Without these figures any plant specification is guesswork, and a plant designed for the wrong water either fails or costs far more to run.

Which tests can I do myself?

TDS with a meter, hardness with a titration kit, pH with a meter or strips, chlorine with DPD tablets, and SDI with a kit. These are the ones needed regularly, so owning the kits pays for itself quickly.

Why does iron matter so much?

Above zero point three ppm it fouls both softener resin and RO membranes, and the fouling is difficult to reverse. Iron removal must come before the softener in the treatment train, not after.

How should a water sample be taken?

Let the water run for a few minutes first rather than taking stagnant pipe water, use a clean container rinsed with the same water, label it with date and sampling point, and deliver it to the laboratory quickly.

Should I test at different times of year?

Yes if possible. Borewell TDS often rises through summer as the water table drops, and surface water turbidity rises sharply in monsoon. Design for the worst case rather than the day you happened to sample.